Valve Hydraulic Test Bench |
 |
|

Valve Hydraulic Test Bench - TIB (PDF Download)
|
|
| 1.Performance Feature - TIB |
|
a.It is mostly suitable for the seal pressure of the flanged straight connection valve and performance test of the valve body strength pressure;The packing method adopts the flange terminal seal,holds the press claw clamp and carries out the working test to the valve flange reverse side.The test result has no the influence of outside force.
b.The valve can turn 90°working during testing,especially suitable for air-tightness.
c.The system equips with the high and low pressure water pump device to be used for the test medium circulation storage.
d.The pressure trial medium is water,air and kerosene that can be selected freely by users.
e.It tests the pressure trial safe protective device.
f.It can match with computer detection data management system. |
|
| 2.Main Technical Parameter&Specification - TIB |
|
Specification |
TIB-100
DN15-100mm |
TIB-200
DN50-200mm |
TIB-300
DN80-300mm |
TIB-400
DN200-400mm |
TIB-500
DN250-500mm |
TIB-600
DN300-600mm |
TIB-800
DN500-800mm |
TIB-1000
DN600-1000mm |
Nominal pressure(MPa) |
1.6-32.0 |
1.6-32.0 |
1.6-32.0 |
1.6-20.0 |
0.6-16.0 |
0.6-16.0 |
0.6-10.0 |
0.3-6.4 |
Moving bracket Row spacing |
Biggest distance (mm) |
700 |
850 |
1100 |
1200 |
1400 |
1500 |
1600 |
2300 |
Smallest distance (mm) |
200 |
250 |
280 |
350 |
450 |
450 |
550 |
650 |
Clamp structure |
Axial row spacing (mm) |
60 |
70 |
85 |
105 |
105 |
110 |
110 |
85 |
Radial row spacing (mm) |
130 |
130 |
200 |
260 |
260 |
260 |
360 |
360 |
Hydraulic system/ work pressure |
Voltage regulating rang (Mpa) |
0-6.3 |
0-6.3 |
0-6.3 |
0-6.3 |
0-6.3 |
0-6.3 |
0-6.3 |
0-6.3 |
Flow (L/min) |
16 |
16 |
16 |
25 |
25 |
40 |
40 |
40 |
High pressure[Boosting] (Mpa) |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
5.0-31.5 |
Electric power |
Low pressure (Mpa) |
0-5.0 |
0-5.0 |
0-5.0 |
0-5.0 |
0-5.0 |
0-5.0 |
0-5.0 |
0-5.0 |
Pressure (v) |
380 |
380 |
380 |
380 |
380 |
380 |
380 |
380 |
Frequency (Hz) |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
Electric machine |
Power (KW) |
2.2 |
2.2 |
2.2 |
3 |
3 |
5.5 |
5.5 |
5.5 |
Grade |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
Size of appearance |
L (mm) |
2600 |
2800 |
3200 |
3400 |
3700 |
3900 |
4200 |
5400 |
B (mm) |
1070 |
1350 |
1450 |
1550 |
1700 |
1950 |
2100 |
2350 |
H (mm) |
1200 |
1300 |
1400 |
1500 |
1500 |
1600 |
1700 |
2300 |
Weight |
kg |
1900 |
2400 |
3000 |
4400 |
4800 |
5500 |
8000 |
12000 |
Note:When some of parameters can't meet customers' requirements, please provide needed technical requirements and specification,we will do special design for you. |
|
| |
| |

Valve Hydraulic Test Bench - TIW (PDF Download)
|
| |
1.Performance Feature - TIW |
| |
a.It's suitable for the welding valve and as well as uses to flange and thread valve extra-high pressure under the condition of matching with the plane seal plate,high and middle pressure performance test,adopts the hydraulic oil cylinder tip press method to carry out the clamp operation.
b.The system equips with the high and low pressure water pump device to be used for the test medium circulation storage.
c.The pressure trial medium is water,air and kerosene that can be selected freely by users.
d.It sests the pressure trial safe protective device.
e.It can match with computer detection data management system |
| |
2.Main Technical Parameter&Specification
- TIW
Specification |
TIW-100
DN15-100mm |
TIW-200
DN50-200mm |
TIW-300
DN80-300mm |
TIW-400
DN100-400mm |
TIW-500
DN200-500mm |
TIW-600
DN300-600mm |
TIW-800
DN400-800mm |
Electricpower |
Pressure
(V) |
380 |
380 |
380 |
380 |
380 |
380 |
380 |
Frequency(Hz) |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
Electricmachine |
Power(KW) |
2.2 |
3.0 |
3.0 |
3.0 |
3.0 |
3.0 |
3.0 |
Grade |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
Highest work pressure of oil pump(Mpa) |
6.3 |
6.3 |
6.3 |
6.3 |
6.3 |
6.3 |
6.3 |
Highest work pressure of hydraulic cylinder(Mpa) |
31.5 |
31.5 |
31.5 |
31.5 |
31.5 |
31.5 |
31.5 |
Highest testing pressure of biggest diameter(Mpa) |
32.0 |
32.0 |
25.0 |
10.0 |
6.4 |
6.4 |
4.0 |
Effective biggest span(mm) |
750 |
1200 |
1350 |
1350 |
1350 |
1350 |
1550 |
Effective smallest span(mm) |
120 |
220 |
250 |
300 |
350 |
400 |
500 |
Highest work pressure of hydraulic pressure supplying seatting |
50.0 |
50.0 |
50.0 |
50.0 |
50.0 |
25.0 |
20.0 |
Size of appearance |
L mm |
2600 |
3100 |
3400 |
3500 |
3600 |
3700 |
4500 |
B mm |
1100 |
1350 |
1500 |
1600 |
1700 |
1800 |
2300 |
H mm |
900 |
1100 |
1150 |
1200 |
1400 |
1500 |
1600 |
Weight |
kg |
2800 |
4200 |
5700 |
6400 |
6800 |
7500 |
8300 |
Note:When some of parameters can't meet customers' requirements, please provide needed technical requirements and specification,we will do special design for you. |
|
|
| Contact Us |
|
Factory Add:Liming Industrial Zone no.1, Wenzhou, Zhejiang,China
Sales Dept:14/F International Trade Centre,No.8 Liming Rd(w). Wenzhou
Tel:+86-577-8873-2275
Fax:+86-577-8873-2276
E-mail:Sales AT Tipvalve.com(AT=@) |
| |
|
|
|